Cena : 560,00 zł Kujawsko-Pomorskie ting0714
14-07-20 0 Odsłon

Cross Linked Insulation Flame Retardant Power Cable of Rated Voltage 8.7/10kV or Lower for Coal Mine Application MT818.13-1999 鈥淐opper core fixed installation flame retardant power cable of rated voltage 10kv or lower for coal mine application---part 3 XLPE insulation power cable for coal mine application鈥? Working Condition Max. working temperature of cable conductor is 90鈩? Max. temperature of cable conductor is no more than 250鈩?during shirt circuit. (The longest lasting time is no more than 5 seconds.) Cable installation temperature is no less than 0鈩? Cable type & name TypeName MYJV Copper core XLPE insulation PVC sheath power cable for coal mine application MYJV22 Copper core XLPE insulation steel tape armoring PVC sheath power cable for coal mine application MYJV32 Copper core XLPE insulation thin steel wire armoring PVC sheath power cable for coal mine application MYJV42 Copper core XLPE insulation thick steel wire armoring PVC sheath power cable for coal mine application Manufacturing range Type Core number (kV) rated voltage 0.6/11.8/33.6/6銆?/66/10銆?.7/10 (mm2) nominal cross section area MYJV31.5~30010~30025~30025~300 MYJV2234~30010~30025~30025~300 MYJV3234~30010~30025~30025~300 MYJV4234~30010~30025~30025~300 The figure of cable structure Product characteristic The cable has good feature of flame resistance. It can meet special requirement of cable for coal mine application. Flame retardant performance of finished cable shall meet all kinds of test requirement stipulated in MT386 standard. Outer diameter size of cable Core number * nominal cross section area of conductor (mm2)Insulated thickness (mm)Sheath thickness (mm)Approx. outer diameter of cable (mm) 3*1.50.71.810.0 3*2.50.71.810.8 3*40.71.811.8 3*60.71.812.8 3*100.71.815.6 3*160.71.818.0 3*250.91.820.6 3*350.91.820.2 3*501.01.823.4 3*701.11.826.4 3*951.11.930.0 3*1201.22.033.2 3*1501.42.137.5 3*1851.62.342.0 3*2401.72.446.4 3*3001.82.651.0 Core number * nominal cross section area of conductor (mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*40.71.814.5 3*60.71.815.6 3*100.71.818.5 3*160.71.820.8 3*250.91.823.5 3*350.91.823.0 3*501.01.826.2 3*701.11.930.5 3*951.12.034.5 3*1201.22.238.0 3*1501.42.342.2 3*1851.62.547.0 3*2401.72.651.6 3*3001.82.856.4 Core number * nominal cross section area of conductor(mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*40.71.815.5 3*60.71.817.5 3*100.71.820.4 3*160.71.823.2 3*250.91.826.0 3*350.91.825.5 3*501.01.828.5 3*701.12.032.0 3*951.12.136.8 3*1201.22.240.0 3*1501.42.445.5 3*1851.62.650.5 3*2401.72.755.0 3*3001.82.960.0 Core number * nominal cross section area of conductor(mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*40.71.824.0 3*60.71.825.0 3*100.71.828.0 3*160.71.930.2 3*250.92.033.2 3*350.92.032.5 3*501.02.136.0 3*701.12.239.5 3*951.12.342.5 3*1201.22.446.0 3*1501.42.650.5 3*1851.62.754.5 3*2401.72.959.5 3*3001.83.063.5 Core number * nominal cross section area of conductor(mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*102.01.823.2 3*162.01.825.5 3*252.01.827.5 3*352.01.929.5 3*502.02.034.0 3*702.02.138.0 3*952.02.342.2 3*1202.02.547.5 3*1502.02.650.0 3*1852.02.753.2 3*2402.02.960.0 3*3002.03.064.0 Core number * nominal cross section area of conductor(mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*102.01.824.0 3*162.01.826.2 3*252.01.828.5 3*352.01.931.5 3*502.02.136.5 3*702.02.340.5 3*952.02.444.5 3*1202.02.549.5 3*1502.02.652.0 3*1852.02.755.2 3*2402.03.062.0 3*3002.03.166.5 Core number * nominal cross section area of conductor(mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*102.01.826.5 3*162.01.828.8 3*252.01.931.0 3*352.02.034.0 3*502.02.138.5 3*702.02.342.8 3*952.02.446.8 3*1202.02.652.8 3*1502.02.754.8 3*1852.02.858.8 3*2402.03.166.8 3*3002.03.271.0 Core number * nominal cross section area of conductor(mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*102.01.931.5 3*162.02.034.0 3*252.02.136.2 3*352.02.138.0 3*502.02.342.8 3*702.02.446.8 3*952.02.550.8 3*1202.02.756.2 3*1502.02.858.5 3*1852.02.962.0 3*2402.03.168.0 3*3002.03.373.0 Core number * nominal cross section area of conductor(mm2)Insulated thickness(mm)Sheath thickness(mm)Approx. outer diameter of cable(mm) 3*252.52.136.0 3*352.52.138.0 3*502.52.241.0 3*702.52.445.0 3*952.52.549.0 3*1202.52.652.0 3*1502.52.756.0 3*1852.52.860.0 3*2402.63.065.0 3*3002.83.271.0 Main technical parameter of cable Max. conductor DC resistance at 20鈩?shall meet the requirement of class 2 conductor stipulated in GB/T3956 standard. Nominal cross section area of conductor(mm2)Max. conductor DC resistance at 20鈩?惟/km Nominal cross section area of conductor(mm2)Max. conductor DC resistance at 20鈩?惟/km 1.512.1500.387 2.57.41700.268 44.61950.193 63.081200.153 101.831500.124 161.151850.0991 250.7272400.0754 350.5243000.0601 A.C. proof-voltage test kV Rated voltage kV0.6/11.8/3 3.6/6 6/6銆?/10 8.7/10 Test voltagekV3.56.5 11 15 22 Test condition: 5 minutes under environment temperature Test requirement: insulation without puncture Partial discharge Rated voltage kV3.6/6 6/6銆?/10 8.7/10 Discharge value pc 10 Cable current loading capacity Please refer to current-loading capacity of common YJV series cross linked power cable.Customized Cable For Coal Mine website:http://www.chinaxintongcable.com/cable-for-coal-mine/

>http://www.chinaxintongcable.com/cable-for-coal-mine/


Wyślij wiadomość

Powiązane ogłoszenia

Skived And Burnished Tube manufacturers

Cold Drawn Hydraulic Cylinder Tubes Introduction Skived and roller burnished tubes are presicion tubes with smooth inside , they also could be skived and burnished pipe. Tubes or pipes inside tolerance could be H10, H9 or H8. Outside tolerance, wall… Kujawsko-Pomorskie

Empty Medicine Capsule

Our History 2001 Company Founded. 2001-2010 Only for the domestic business 2010 Standardize the Capsule Production Process 2013 Obtain Import and Export Certificate. Upgrade the empty capsule automatic production line 2014 Sole Proprietorship and… Kujawsko-Pomorskie

Nespresso Capsule quotation

Onwin CM02 Nespresso pods capsules Best Compatibility Our capsules are compatible with all Nespresso庐 machines, including SINO, Krups, Magimix, Miele, Delonghi, Essenza, Citiz, Cub, Siemens , Pixie and also the latest Nepresso庐 U Nespresso庐 machine.… Kujawsko-Pomorskie

Air Blade Hand Dryer suppliers

 Descriptions of gorillo hand dryer Material: ABS Color: White, Silver, grey, black etc Rated voltage: 220V (other voltage is available according to your country) Input power: 1650W Rated frequency: 50Hz Size: 250x190x520mm Wind speed: 90m/s Dying time:… Kujawsko-Pomorskie

Electric Pallet Truck suppliers

GS electric pallet truck is your perfect assistant in short distance horizontal palletized cargo transportation.With the power of electric and motor,no need to move the heavy goods just by your own body strength,just focus on the technology the electric… Kujawsko-Pomorskie

Zgłoś tę reklamę

Udostępnij