Internet uebb9u
25-09-20 0 Odsłon

ISO 80369-7 FIGURE C.4 and C.6 Male Luer Reference Connector Made of Hardness Steel ISO 80369-7:2016 cancels and replaces the first edition ISO 594-1:1986 and the second edition of ISO 594-2:1998, clauses, subclauses, tables, figures, and annexes of which have been consolidated and technically revised. Because of this, ISO 594 connections must be tested per ISO 80369-7 requirements. Read: Discussion on the change. Compatibility/Interchangeability... Between ISO 594/2 Fig 7 and ISO 80369-7 Fig C.4 The ISO 594/2 Figure 7 Male Luer Reference Conical Fitting is replaced by ISO 80369-7 Fig C.4 Male Luer Reference Connector. The ISO 80369-7 Figure C.4 is identical to the ISO 594/2 Figure 7 Reference Fitting. ISO 80369-7 Fig C.4 and ISO 594/2 Fig 7 are completely interchangeable. If you request a quote for a new ISO 594/2 Fig 7 Reference Connector from us; we will quote an item which will pass both ISO 594 and ISO 80369-7 requirements. It will be DUO-marked and DUO-certified to both specifications. Between ISO 594/2 Fig 8 and ISO 80369-7 Fig C.6 The ISO 594/2 Figure 8 Male Luer Reference Conical Fitting is replaced by ISO 80369-7 Fig C.6 Male Luer Reference Connector. The ISO 80369-7 Figure C.6 is identical to the ISO 594/2 Figure 8 Reference Fitting. ISO 80369-7 Fig C.6 and ISO 594/2 Fig86 are completely interchangeable. If you request a quote for a new ISO 594/2 Fig 8 Reference Connector from us; we will quote an item which will pass both ISO 594 and ISO 80369-7 requirements. It will be DUO-marked and DUO-certified to both specifications. General Construction Details: Keeping with the requirements of ISO 80369-7; the Reference Connectors we sell are from hardened stainless steel. They have design details which are not specified in ISO 80369-7 and which allow connection to test equipment. These design details vary by manufacturer so be sure you understand the configuration before you order the Reference Connector. The ISO 80369 Reference Connectors are an integral part of Luer needle and syringe testing. Uses for... ISO 80369-7 Fig C.4 The ISO 80369-7 Figure C.4 Male Luer Reference Connectors are used for testing Female Luer Connectors for: Leakage; Separation from unscrewing; Stress cracking; and Non-interconnectable characteristics in the ISO 80369-7; Clause 6 specified tests. Below is the list of tests which are accomplished by using the ISO 80369-7 Fig C.4 Male Luer Reference Connector: ISO 80369-7 Clause... 4.1: Non-Interconnectivity 6.1: Fluid Leakage 6.2: Sub-Atmospheric Pressure Air Leakage 6.3: Stress Cracking 6.5: Resistance To Separation From UnscrewingChina Medical Test Equipment website:http://www.kingpodg.com/medical-test-equipment/


Wyślij wiadomość

Powiązane ogłoszenia

Pellets Activated Carbon suppliers

This type of activated carbon mainly involves the scope of catalytic carrier activated carbon, alkali-loaded activated carbon, a variety of carrier activated carbon. The basic carbon iodine value distribution range, the basic range of CTC% of basic carbon… Internet

Stainless Steel Reducer Tee

Our History Wenzhou MingLi Pipeline Co., Ltd is a manufacturer specialized in producing elbows, pipes ,tees, stub ends,reducing pipes;pipe caps and flange etc in Wenzhou,CHINA . We have skilled labour in charge of production, and well trained R&D… Internet

Customized Standing Flower Rack

Our History The company is located in Longquan City, Zhejiang Province, known as Linhai. The company was founded in 2002, after several years of hard work, development and growth, now has a strong economic and technical strength and modern professional… Internet

BS Fuse, UK Plug Fuse factory

Rated Current: 3A,5A,10A,13A Interrupting Capacity Rated Voltage: 240v Other Capacity Certificates: ASTA Material: Ceramic tube Environmental protection: RoHS, Reach Production capability: 600 Thousand pieces per day, full automatic production 12… Internet

Two Arms Towel Bar price

 "NSODOO" is a professional manufacturer, we specialized in bathroom accessories business for 20 years. Our factory was established in 1999, and has more than 7000 square meters of standardized factories. At the same time, having professional talents is a… Internet

Zgłoś tę reklamę

Udostępnij